roovie
Portfolio scale · generate · simulate · report

From one building
to thousands.

Apply modeling profiles. Mass-update assemblies. Run baseline + ECM simulations. Calibrate to real meter data. Rank upgrades. Benchmark against CBECS.

GenerateMass updateSimulateCalibrateRankReport
Client Portal Coming SoonContact
The Roovie pipeline
01
Generate
Profile → portfolio
02
Mass update
Edit once · 248 rows
03
Simulate
Baseline + ECM
04
Calibrate
Meter · CVRMSE ≤ 15%
05
Rank
Payback · savings · CO₂
06
Report
CBECS peer benchmark
Modeling profiles · bulk generation

Apply one modeling profile — to a whole portfolio.

A modeling profile captures every default Roovie needs to build a full energy model: envelope, HVAC, lighting, occupancy, schedules. Apply one profile to hundreds of buildings and the entire portfolio gets generated in parallel.

Modeling profile
Office · 1980s Vintage
ashrae-901-1989 · cz-2A · medium-office
EnvelopeMass wall · R-13 · WWR 0.38
HVACPVAV + boiler · IEER 10.5
Lighting1.1 W/ft² · T8 lamps
OccupancyOffice · 250 ft²/person
SchedulesASHRAE 90.1 default · 5-day
▤ Portfolio · 248 buildings · bulk-selected▤ 248 buildings0/ 248 generated
Mass update · baseline + ECM simulations

Edit once. Simulate all of them.

Select every building in the portfolio. Change a single field — a COP, a WWR, a lighting power density — and Roovie propagates the edit across every model, then runs baseline + ECM simulations in parallel on the cloud.

☑ 248 selected
hvac.cooling_cop4.00
Building◇ Baseline◉ ECMΔ EUI
Dallas Tower A#100
EUI 81
EUI 61
−25%
Houston Plaza#101
EUI 94
EUI 66
−30%
Austin Medical#102
92%
78%
Phoenix Office#103
EUI 118
68%
San Antonio HQ#104
EUI 72
EUI 54
−25%
El Paso Annex#105
52%
31%
Fort Worth Labs#106
EUI 104
EUI 74
−29%
Corpus Data Ctr#107
38%
18%
Parallel runs — baseline and ECM bundles in one pass across 248 buildings in ~11 minutes.
Calibrate to meters · rank ECMs

Calibrate against real meters. Rank what to do first.

Auto-tune infiltration, plug loads, and schedules against 12 months of utility meter data until CVRMSE drops below 15% — the ASHRAE Guideline 14 threshold. Then rank every ECM in the library by payback, savings, and carbon.

Calibration · shared utility meter
Portfolio bundle · 12-month meter
ASHRAE G14 pass
CVRMSE
8.2%
Target ≤ 15%
NMBE
1.3%
Target ≤ 5%
Buildings linked
248
All selected
Iterations
48
Auto-tune
Auto-tuner adjusts infiltration, lighting density, plug loads, and schedules. Auto-tuner · 4 parametersConverged in 4.2s
ECM ranking, sorted by payback
Portfolio-wide priorities
↓ Sort by payback
#MeasurePayback
1
VFD on AHU supply fans
hvac$256k/yr−114 tCO₂e
1.9
years
2
Demand-controlled ventilation
hvac$188k/yr−84 tCO₂e
2.0
years
3
LED retrofit · full
lighting$412k/yr−184 tCO₂e
2.4
years
4
Window film · south façade
envelope$124k/yr−55 tCO₂e
2.8
years
5
Roof R-30 → R-45
envelope$288k/yr−128 tCO₂e
4.1
years
6
Heat-recovery chiller
hvac$512k/yr−228 tCO₂e
8.2
years
Benchmarked against CBECS 2018 peers·Median EUI 82.4·Your portfolio 68.1 kBtu/ft²·34th percentile ▼
Capability coverage · 52 evaluated

Every other tool covers a slice. Roovie covers all of it.

The industry has converged on EnergyPlus — desktop suites, HVAC platforms, compliance tools, even AI builders are skins on the same engine. Roovie ships its own physics and wraps it in the workflow layer nobody else built.

Full
Partial
None
CapabilityDesktopHVACEarly-DesignOpen-SourceComplianceAI BuildersGov HPCRoovie
AI building creation assistant
AI material & assembly agent
AI HVAC configuration agent
AI error diagnosis & debugging
AI-powered report generation
AI document analysis (chat over docs)
AI simulation insights & calibration
AI template recommendations
Autonomous building generation & analysis
Total — 52 possible16.58129.56.58852

Everyone else forces you to bolt together 3–5 separate tools (plus Excel, plus email). Roovie handles it all in one place.

Report at scale · CBECS benchmark

Generate. Simulate. Report.

Every simulation feeds a shared report layer. Rollups, charts, and audit-ready narrative — benchmarked against CBECS peers and packaged into client-ready PDFs or shareable portals.

Buildings modeled
248
94 cities · 12 climate zones
Simulations run
496
baseline + ECM bundle
Meters calibrated
248
ASHRAE G14 · CVRMSE 8.2%
Portfolio Δ EUI
−27%
18.3 GWh · 4,812 tCO₂e/yr
Total runtime
11 min
vs weeks of manual work
▣ CBECS 2018 benchmark — portfolio EUI distribution
Your portfolio vs. peer set (medium office, mixed-humid)
CBECS peers
Your portfolio
Traditional workflow
Months
Orders of magnitude faster
With Roovie, at scale
Minutes
Client Portal Coming SoonContact
Generate Mass update Simulate Calibrate Rank Report — at portfolio scale